85926 | CVE-2017-5176 | A DLL Hijack issue was discovered in Rockwell Automation Connected Components Workbench (CCW). The following versions are affected: Connected Components Workbench - Developer Edition, v9.01.00 and earlier: 9328-CCWDEVENE, 9328-CCWDEVZHE, 9328-CCWDEVFRE, 9328-CCWDEVITE, 9328-CCWDEVDEE, 9328-CCWDEVESE, and 9328-CCWDEVPTE; and Connected Components Workbench - Free Standard Edition (All Supported Languages), v9.01.00 and earlier. Certain DLLs included with versions of CCW software can be potentially hijacked to allow an attacker to gain rights to a victim's affected personal computer. Such access rights can be at the same or potentially higher level of privileges as the compromised user account, including and up to computer administrator privileges. | 2 | 6.2 | Medium | 2017-06-03 | 2017-06-02 | View | |
86210 | CVE-2017-9098 | ImageMagick before 7.0.5-2 and GraphicsMagick before 1.3.24 use uninitialized memory in the RLE decoder, allowing an attacker to leak sensitive information from process memory space, as demonstrated by remote attacks against ImageMagick code in a long-running server process that converts image data on behalf of multiple users. This is caused by a missing initialization step in the ReadRLEImage function in coders/rle.c. | 2 | 5 | Medium | 2017-06-03 | 2017-06-02 | View | |
86211 | CVE-2017-9100 | login.cgi on D-Link DIR-600M devices with firmware 3.04 allows remote attackers to bypass authentication by entering more than 20 blank spaces in the password field during an admin login attempt. | 2 | 8.3 | High | 2017-06-03 | 2017-06-02 | View | |
86229 | CVE-2017-9138 | There is a debug-interface vulnerability on some Tenda routers (FH1202/F1202/F1200: versions before 1.2.0.20). After connecting locally to a router in a wired or wireless manner, one can bypass intended access restrictions by sending shell commands directly and reading their results, or by entering shell commands that change this router's username and password. | 2 | 7.7 | High | 2017-06-03 | 2017-06-02 | View | |
86230 | CVE-2017-9139 | There is a stack-based buffer overflow on some Tenda routers (FH1202/F1202/F1200: versions before 1.2.0.20). Crafted POST requests to an unspecified URL result in DoS, interrupting the HTTP service (used to login to the web UI of a router) for 1 to 2 seconds. | 2 | 2.7 | Low | 2017-06-03 | 2017-06-02 | View |